Typical Properties of Gap Filler 2000 |
|||||
| Property | Imperial Value |
Metric Value |
Test Method |
||
| Color / Part A | Pink |
Pink |
Visual |
||
| Color / Part B | White |
White |
*** |
||
| Viscosity as Mixed (cps)(1) | 300,000 |
300,000 |
ASTM D2196 |
||
| Density (g/cc) | 2.9 |
2.9 |
ASTM D792 |
||
| Mix Ratio | 1:1 |
1:1 |
*** |
||
| Shelf Life @ 25ºC (months) | 6 |
6 |
*** |
||
| Property As Cured | |||||
| Color | Pink |
Pink |
Visual |
||
| Hardness (Shore 00)(2) | 70 |
70 |
ASTM D2240 |
||
| Heat Capacity (J/g-K) | 1.0 |
1.0 |
ASTM E1269 |
||
| Continuous Use Temp (°F) / (°C) | -76 to 392 |
-60 to 200 |
*** |
||
| Electrical As Cured | |||||
| Dielectric Strength (V/mil) | 500 |
500 |
ASTM D149 |
||
| Dielectric Constant (1000 Hz) | 7 |
7 |
ASTM D150 |
||
| Volume Resistivity (Ohm-meter) | 1011 |
1011 |
ASTM D257 |
||
| Flame Rating | V-O |
V-O |
U.L. 94 |
||
| Thermal As Cured | |||||
| Thermal Conductivity (W/m-K) | 2.0 |
2.0 |
ASTM D5470 |
||
| CURE SCHEDULE | SCHEDULE 1 |
SCHEDULE 2 |
SCHEDULE 3 |
||
| Pot Life @ 25ºC (min)(3) | 15 min |
60 min |
600 min (10 hr) |
||
| Cure @ 25ºC (min)(4) | 1-2 hours |
3-4 hours |
3 days |
||
| Cure @ 100ºC (min)(4) | 5 min |
15 min |
1 hour |
||
1) Brookfield RV, Heli-Path, Spindle TF @ 20 rpm, 25°C. 2) Thirty second delay value Shore 00 hardness scale. 3) Time for viscosity to double. 4) Cure schedule (rheometer - time to read 90% cure) |
|||||