Typical Properties of Gap Pad 2200SF |
|||||
| Property | Imperial Value |
Metric Value |
Test Method |
||
| Color | Green |
Green |
Visual |
||
| Reinforcement Carrier | Fiberglass |
Fiberglass |
*** |
||
| Thickness (inch) / (mm) | 0.010 to 0.125 |
0.254 to 3.175 |
ASTM D374 |
||
| Inherent Surface Tack (1 or 2 sided) | 2 |
2 |
*** |
||
| Density (g/cc) | 2.8 |
2.8 |
ASTM D792 |
||
| Heat Capacity (J/g-K) | 1.0 |
1.0 |
ASTM E1269 |
||
| Hardness, Bulk Rubber (Shore 00) (1) | 70 |
70 |
ASTM D2240 |
||
| Young's Modulus (psi) / (kPa) (2) | 33 |
228 |
ASTM D575 |
||
| Continuous Use Temp (°F) / (°C) | -76 to 257 |
-60 to 125 |
*** |
||
| Electrical | |||||
| Dielectric Breakdown Voltage (Vac) | >5000 |
>5000 |
ASTM D149 |
||
| Dielectric Constant (1000 Hz) | 6.0 |
6.0 |
ASTM D150 |
||
| Volume Resistivity (Ohm-meter) | 108 |
108 |
ASTM D257 |
||
| Flame Rating | V-O |
V-O |
U.L. 94 |
||
| Thermal | |||||
| Thermal Conductivity (W/m-K) | 2.0 |
2.0 |
ASTM D5470 |
||
1) Thirty second delay value Shore 00 hardness scale. 2) Young's Modulus, calculated using 0.01 in/min. step rate of strain with a sample size of 0.79 inch2. For more information on Gap Pad modulus, refer to Bergquist Application Note #116. |
|||||