Typical Properties of Gap Pad 2500S20 |
|||
| Property | Imperial Value |
Metric Value |
Test Method |
| Color | Light Yellow |
Light Yellow |
Visual |
| Reinforcement Carrier | Fiberglass |
Fiberglass |
*** |
| Thickness (inch) / (mm) | 0.010 to 0.250 |
0.254 to 6.350 |
ASTM D374 |
| Inherent Surface Tack (1 side) | 2 |
2 |
*** |
| Density (g/cc) | 3.1 |
3.1 |
ASTM D792 |
| Heat Capacity (J/g-K) | 1.0 |
1.0 |
ASTM E1269 |
| Hardness (Bulk Rubber) (Shore 00) (1) | 20 |
20 |
ASTM D2240 |
| Young's Modulus (psi) / (kPa) (2) | 5 |
35 |
ASTM D575 |
| Continuous Use Temp (°F) / (°C) | -76 to 392 |
-60 to 200 |
*** |
| Electrical | |||
| Dielectric Breakdown Voltage (Vac) | >3000 |
>3000 |
ASTM D149 |
| Dielectric Constant (1 Mhz) | 6.6 |
6.6 |
ASTM D150 |
| Volume Resistivity (Ohm-meter) | 1011 |
1011 |
ASTM D257 |
| Flame Rating | V-O |
V-O |
U.L. 94 |
| Thermal | |||
| Thermal Conductivity (W/m-K) | 2.4 |
2.4 |
ASTM D5470 |
| Thermal Performance vs. Strain | |||||
| Deflection (% strain) | 10 |
20 |
30 |
||
| Thermal Impedance (°C-in2/W) 0.040" (3) | 0.75 |
0.68 |
0.61 |
||
| Thermal Impedance (°C-cm2/W) 1.016mm (3) | 4.8 |
4.4 |
3.9 |
||
1) Thirty second delay value Shore 00 hardness scale. 2) Young's Modulus, calculated using 0.01 in/min. step rate of strain with a sample size of 0.79 inch2. 3) The ASTM D5470 test fixture was used. The recorded value includes interfacial thermal resistance. These values are provided for reference only. Actual application performance is directly related to the surface roughness, flatness and pressure applied. |
|||||