Typical Properties of Hi-Flow 225U |
|||
| Property | Imperial Value |
Metric Value |
Test Method |
| Color | Black |
Black |
Visual |
| Reinforcement Carrier | None |
None |
*** |
| Thickness (inch) / (mm) | 0.0015 |
0.036 |
ASTM D374 |
| Continuous Use Temp (°F) / (°C) | 302 |
150 |
*** |
| Phase Change Temp (°F) / (°C) | 131 |
55 |
ASTM D3418 |
| Electrical | |||
| Flame Rating | V-O |
V-O |
U.L. 94 |
| Thermal | |||
| Thermal Conductivity (W/m-K) (1) | 1.0 |
1.0 |
ASTM D5470 |
| Thermal Performance vs Pressure | |||
| Pressure (psi) | 10 |
25 |
50 |
100 |
200 |
| TO-220 Thermal Performance (ºC/W) | 0.53 |
0.47 |
0.39 |
0.34 |
0.32 |
| Thermal Impedance (ºC-in2/W) (2) | 0.08 |
0.07 |
0.06 |
0.05 |
0.04 |
1) This is the measured thermal conductivity of the Hi-Flow coating. It represents one conducting layer in a three-layer laminate. The Hi-Flow coatings are phase change compounds. These layers will respond to heat and pressure induced stresses. The overall conductivity of the material in post-phase change, thin film products is highly dependent upon the heat and pressure applied. This characteristic is not accounted for in ASTM D5470. Please contact Bergquist Product Management if additional specifications are required. 2) The ASTM D5470 test fixture was used and the test sample was conditioned at 70°C prior to test. The recorded value includes interfacial thermal resistance. These values are provided for reference only. Actual application performance is directly related to the surface roughness, flatness and pressure applied. |
|||||