Typical Properties of Sil-Pad 800 |
|||
| Property | Imperial Value |
Metric Value |
Test Method |
| Color | Gold |
Gold |
Visual |
| Reinforcement Carrier | Fiberglass |
Fiberglass |
*** |
| Thickness (inch) / (mm) | 0.005 |
0.127 |
ASTM D374 |
| Hardness (Shore A) | 91 |
91 |
ASTM D2240 |
| Elongation (%45º to Warp and Fill) | 20 |
20 |
ASTM D1412 |
| Tensile Strength (psi) / (MPa) | 1700 |
12 |
ASTM D412 |
| Continuous Use Temp (°F) / (°C) | -76 to 356 |
-60 to 180 |
*** |
| Electrical | |||
| Dielectric Breakdown Voltage (Vac) | 3000 |
3000 |
ASTM D149 |
| Dielectric Constant (1000 Hz) | 6.0 |
6.0 |
ASTM D150 |
| Volume Resistivity (Ohm-meter) | 1010 |
1010 |
ASTM D257 |
| Flame Rating | V-O |
V-O |
U.L. 94 |
| Thermal | |||
| Thermal Conductivity (W/m-K) | 1.6 |
1.6 |
ASTM D5470 |
| Thermal Performance vs Pressure | |||
| Pressure (psi) | 10 |
25 |
50 |
100 |
200 |
| TO-220 Thermal Performance (ºC/W) | 3.56 |
3.01 |
2.45 |
2.05 |
1.74 |
| Thermal Impedance (ºC-in2/W) (1) | 0.92 |
0.60 |
0.45 |
0.36 |
0.29 |
1) The ASTM D5470 test fixture was used. The recorded value includes interfacial thermal resistance. These values are provided for reference only. Actual application performance is directly related to the surface roughness, flatness and pressure applied. |
|||||