Typical Properties of Sil-Pad Tube 400 |
|||
| Property | Imperial Value |
Metric Value |
Test Method |
| Color | Gray/Green |
Gray/Green |
Visual |
| Thickness / Wall (inch) / (mm) | 0.012 |
0.305 |
ASTM D374 |
| Hardness (Shore A) | 80 |
80 |
ASTM D2240 |
| Breaking Strength (lbs/inch) / (kN/m) | 6 |
1 |
ASTM D1458 |
| Continuous Use Temp (°F) / (°C) | -76 to 356 |
-60 to 180 |
*** |
| Electrical | |||
| Dielectric Breakdown Voltage (Vac) | 5000 |
5000 |
ASTM D149 |
| Dielectric Constant (1000 Hz) | 5.5 |
5.5 |
ASTM D150 |
| Volume Resistivity (Ohm-meter) | 1011 |
1011 |
ASTM D257 |
| Flame Rating | V-O |
V-O |
U.L. 94 |
| Thermal | |||
| Thermal Conductivity (W/m-K) | 0.9 |
0.9 |
ASTM D5470 |
| Thermal Impedance (ºC-in2/W) (1) | 0.6 |
0.6 |
ASTM D5470 |
Typical Properties of Sil-Pad Tube 1000 |
|||||
| Property | Imperial Value |
Metric Value |
Test Method |
||
| Color | Brown |
Brown |
Visual |
||
| Thickness (inch) / (mm) | 0.012 |
0.030 |
ASTM D374 |
||
| Hardness (Shore A) | 80 |
80 |
ASTM D2240 |
||
| Breaking Strength (lbs/inch) / (kN/m) | 6 |
1 |
ASTM D1458 |
||
| Continuous Use Temp (°F) / (°C) | -76 to 356 |
-60 to 180 |
*** |
||
| Electrical | |||||
| Dielectric Breakdown Voltage (Vac) | 5000 |
5000 |
ASTM D149 |
||
| Dielectric Constant (1000 Hz) | 4.5 |
4.5 |
ASTM D150 |
||
| Volume Resistivity (Ohm-meter) | 1011 |
1011 |
ASTM D257 |
||
| Flame Rating | V-O |
V-O |
U.L. 94 |
||
| Thermal | |||||
| Thermal Conductivity (W/m-K) | 1.2 |
1.2 |
ASTM D5470 |
||
| Thermal Impedance (ºC-in2/W) (1) | 0.4 |
0.4 |
ASTM D5470 |
||
1) The ASTM D5470 test fixture was used. The recorded value includes interfacial thermal resistance. These values are provided for reference only. Actual application performance is directly related to the surface roughness, flatness and pressure applied. |
|||||